The positioning cylinders operate a valve that controls the mass flow needed to drive machinery. Voith I/H
converters ensure very precise and highly dynamic control of the mass flow. I/H converters change a constant
input pressure into a variable output pressure. A standard 0/4 – 20 mA signal specifies the output pressure.
The major components of the I/H converter are a hydraulic unit and a force-controlled electromagnet.
The I/H converter features a simple and compact design. This ensures reliable operation. The Mean Time
Between Failures (MTBF) for Voith I/H converters is over 600 years. Your equipment runs for a very long
period of time without unplanned downtime; availability is increased.
Specifications
Flow rate |
Up to 140 l/min at 1 bar differential pressure |
Input pressure |
Up to 70 bar |
Supply voltage |
24 VDC |
Current consumption |
1.0 A (3.0 A for t < 1 s) |
Input signal |
0/4 – 20 mA |
Ambient temperature |
-20 to +80°C (standard version, not rated for use in potentially explosive areas) |
Explosion proof rating (optional) |
ATEX (II 2G IIC T4) or FM/CSA (Class 1, Div. 1, 2, Group B, C, D,Temp. Code T4) |
Protection class |
IP 65 |
Safety class |
SIL 2 (on request) |
|